Backflow Devices

A Backflow prevention device is used to protect potable water supplies from contamination or pollution due to backflow.

Backflow Prevention Devices

In addition to being a leader in the fire protection industry, our team at Chief Facility Defense are experts with the installation, testing and maintenance of Backflow prevention systems. Chief Facility Defense’s firefighter experience and knowledge allows us to keep your systems running correctly and in compliance with code.

You can count on Chief Facility Defense for your Backflow installation, testing and maintenance.

Service & Certification

Each year a back flow system must be tested and certified.

Each jurisdiction may have different requirements that need to be met. Backflow devices are mechanical and have metal, plastic and rubber parts that need to be checked and verified they are in working condition. These parts are under constant water pressure and are susceptible to failure. They will need replacement or repair. On occasion a complete replacement will need to be done in order to uphold the integrity of the water system.

What is Backflow?

Backflow is a term in for an unwanted flow of water in the reverse direction.

This can be a serious health risk for the contamination of potable water supplies with foul water. In the most obvious case, a toilet flush cistern and its water supply must be isolated from the toilet bowl. For this reason, building codes mandate a series of measures and backflow prevention devices to prevent backflow.

In water distribution systems, water is normally maintained at a significant pressure to enable water to flow from the tap, shower, or other fixture. Water pressure may fail or be reduced when a water main bursts, pipes freeze, or there is unexpectedly high demand on the water system (for example, when several fire hydrants are opened). Reduced pressure in the pipe may allow contaminated water from the soil, from storage, or from other sources to be drawn up into the system.

Backflow occurs for one of two reasons, either back pressure or back siphonage.
1) Back pressure is the result of a higher pressure in the system than in its supply, i.e. the system pressure has been increased by some means. This may occur in unvented heating systems, where thermal expansion increases the pressure.
 
2) Back siphonage is the result of supply pressure being lowered below that of the system. This may occur when a supply is interrupted or drained down.